40G Full rate BERT
- Series: BERT - Brand: Te-lead
Applications:
l Transceiver-module R&D and production
l Optical-component/sub-system R&D and production
l Fibre-optic communication systems
l Satellite-communication systems
l High-speed digital interfaces and bus standards (USB, Ethernet, Fibre Channel, etc.)
l Incoming-quality inspection and production testing for system vendors
l System installation and fault location
The bit-error-rate tester is an indispensable instrument for researchers and field engineers developing and debugging all of the above communication systems.
Key Features:
Typical Data Rate: 155M、622M、1.25G、2.125G、2.488G、2.5G、2.67G、3.125G、4.25G、6.144G、6.25G、8.5G、9.95G、10.3G、10.71G、11.1G、11.3G、12.5G,14G & 15G;
Support any data rate 155Mbps-16.5Gbps
Pattern Supports: PRBS 27 -1、PRBS 29 -1、PRBS 215 -1、PRBS 223 -1、PRBS 231 -1;
Application Interfaces:
l Trigger Output: single-ended, AC-coupled
l External Clock Input: allows external data to be synchronized to the supplied external clock
l Electrical Output: differential, AC-coupled, data inversion supported
l Electrical Input: differential, AC-coupled, data inversion supported
l Single-ended input: 50 Ω termination provided
Other Interfaces:
l Chassis ground stud
l 220 V AC power inlet
l One USB 2.0 port
Parameters | Unit | Min | Typ | Max | Note | |||
Pattern Generator | ||||||||
Channels | 4 | Differential output; | ||||||
Data Rate | Mbit/s | 155 | / | 15200 | ||||
Frequency Accurancy | ppm | -50 | / | 50 | ||||
Electrical Output Swing (Diff) | mV | 200 | 600 | 1200 | ||||
CLK Out Amplitude | mV | 100 | / | 500 | ||||
Output Level Accurancy | % | / | 5 | 8 | ||||
Output Impedance | OHM | 45 | 50 | 55 | Single End | |||
Trigger Frequency | MHz | 77.76 | / | 3800 | >7.4Gbps Div 1/4,<7.4Gbps Div 1/2 | |||
Rise Time(ps,20%~80%) | CH1~CH4 | 0 | / | 40 | It is related to data rate, except data rate<1Gbps | |||
Fall Time(ps,80%~20%) | CH1~CH4 | 0 | / | 40 | ||||
Jitter pk-pk(ps) | CH1~CH4 | 0 | / | 20 | ||||
Jitter rms(ps) | CH1~CH4 | 0 | / | 3 | ||||
Cross point(%) | CH1~CH4 | 40 | 50 | 60 | ||||
Error Detector | ||||||||
Channels | 4 | Differential Input; | ||||||
Data Rate | Mbit/s | 155M | / | 15200 | ||||
Electrical Input(Diff) | mV | 200 | 600 | 1200 | ||||
Input Impedance | OHM | 45 | 50 | 55 | 单端 | |||
External Reference CLK | MHz | 0 | 700 | |||||
General Specifications | ||||||||
SMA Connector | RCLin | External reference CLK input(Customized) | ||||||
Tri | BERT’s Trigger Signal output | |||||||
CH1 | TX+/- | BERT CH1 differential output | ||||||
RX+/- | BERT CH1 differential input | |||||||
CH2 | TX+/- | BERT CH2 differential output | ||||||
RX+/- | BERT CH2 differential input | |||||||
CH3 | TX+/- | BERT CH3 differential output | ||||||
RX+/- | BERT CH3 differential input | |||||||
CH4 | TX+/- | BERT CH4 differential output | ||||||
RX+/- | BERT CH4 differential input | |||||||
USB Interface | USB2.0 | |||||||
RF connector | 17pcs SMA connector | 3.5mm Female | ||||||
Input Power | V | 100-240VAC 50Hz/60Hz | ||||||
GND | BERT接地柱 | |||||||
Power Consumption | W | ≤30W | ||||||
Operation Temperature | ℃ | -10—+55 | ||||||
Storage Temperature | ℃ | -40—+85 | ||||||
Operation Humidity | %RH | 10%~95% | ||||||
Storage Humidity | %RH | 15%~90% | ||||||
Size | mm | 360*105*240 | ||||||
Weight | KG | 4 | ||||||
Pre-heat | Min | 30 Minutes | ||||||
Cooling requirement | / | At least 50mm space each side | ||||||
Model No. | Product Description |
RS1516A-4 | 155M-15.2G Full Rate BERT/4 Electrical channels; |
Option | Extend to 3 Years Warranty |